How to calculate the flow rate of the filter element

How to calculate the flow rate of the filter element

Guangzhou Filter Source Water Purification Equipment Co., Ltd. is the most professional and most powerful filter material and filtration equipment manufacturer in China. The products are exported to more than 20 countries and regions. Today, Xiaotao will tell you about how the filter flow can be calculated.

Filter element - air filter element - water filter element - oil filter element is mainly used in oil filtration, air filtration, water filtration and other filtration industries. It is the filter element that removes a small amount of solid particles in the liquid or air to protect the normal operation of the equipment or the cleanliness of the air. When the fluid enters the filter element with the filter of a certain size, the impurities are blocked, and the cleaned flow passes through the filter element. .

Generally, the filter element is generally external pressure type filtration, so the filtration area can be calculated. The conventional filter element has an outer diameter of 63 mm, an inner diameter of 30 m, and a length of 40 inches of 1016 mm. Therefore, the filtration area is: 3.14*63/1000*1.016=0.2 square meters.
Generally, the forced filtration flux is not allowed to exceed 10 cubic meters per square meter·h, so the calculation can be concluded that the water output of a single filter element is 0.2*10=2 tons/hour, so the maximum output of a single 40-inch filter element is 2 tons/hour. The maximum output of 30 inches is 1.5 tons / hour, 20 inches is 1 ton / hour, 10 inches is 0.5 tons / hour, and the filter element commonly used in industrial water treatment is 40 inches, so the maximum water output of the security filter filter is 2 tons / Hours to consider, of course, conservative calculations, each 40-inch filter is 1.5 tons / h, 1 ton / h is also possible.