MR-700 with LCD touch screen  Phototherapy Unit  Pulse Oximetry Function features  Microprocessor based servo controlled temperature system  The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic  APGAR timer to record therapy time  Audible and visual  Alarm functions :  Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature  LED observation light adjustable,brightness adjustable  Heater head can be adjusted  ±90°horizontally  Convenient X-ray cassette board under infant bed  Tilt angle of infant bed is adjustable  Four Transparent protector folded with 2 infusion seals  With RS-232 connector,2 trays and 2 drawers  Skin temp T1,T2; Temp value and trend on 8″LCD Touch screen  Pulse oximetry, APGAR timer and other parameters display on 8″LCD  screen  BL -60D Phototherapy unit,Sillicone Ambu-bag set, Laryngoscope set Technical data Power supply                              AC110/220V   60/50Hz Power input                               1000VA                   Environment temperature                    18ºC~30ºC Operating          Environment relative humidity                 30%~75% conditions          Atmospheric Pressure                        700~1060hpa                   Environment air velocity of flow                 <0.3m/s Skin Temperature control range                                   32ºC~38ºC Skin temperature control accuracy                                 ≤0.5ºC Skin temperature sensor accuracy                                 ±0.3ºC Mattress temperature uniformity                                  <2ºC Infant Bed tilt angle                                              ±10° LED observation light function                                      3W Warm-up time(from 25ºC)                                        <30min Heater head horizontal                                            ±90° Distance from heater to mattress                                   80cm Mattress size                                                   67cmX54cm              APGAR Timer range                               0~99h59min,singal per min at first 1h Heating power                            0-100%in5%step                                                                    Phototherapy Irradiance                                          20-70μw/c/nm Standard configuration Main body (including the Radiant source, Control system,Infant bed, Bracket), X-ray cassette , Observe light ,I.V.pole, Skin temperature sensor, Tray, Mattress, Transparent protector, Castors , Drawers Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral) Reusable AMBU bag for child - 2 pcs Reusable AMBU bag for adult - 2 pcs  Reusable laryngoscope 1 pcs MR-700 with LCD touch screen  Phototherapy Unit  Pulse Oximetry Function features  Microprocessor based servo controlled temperature system  The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic  APGAR timer to record therapy time  Audible and visual  Alarm functions :  Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature  LED observation light adjustable,brightness adjustable  Heater head can be adjusted  ±90°horizontally  Convenient X-ray cassette board under infant bed  Tilt angle of infant bed is adjustable  Four Transparent protector folded with 2 infusion seals  With RS-232 connector,2 trays and 2 drawers  Skin temp T1,T2; Temp value and trend on 8″LCD Touch screen  Pulse oximetry, APGAR timer and other parameters display on 8″LCD  screen  BL -60D Phototherapy unit,Sillicone Ambu-bag set, Laryngoscope set Technical data Power supply                              AC110/220V   60/50Hz Power input                               1000VA                   Environment temperature                    18ºC~30ºC Operating          Environment relative humidity                 30%~75% conditions          Atmospheric Pressure                        700~1060hpa                   Environment air velocity of flow                 <0.3m/s Skin Temperature control range                                   32ºC~38ºC Skin temperature control accuracy                                 ≤0.5ºC Skin temperature sensor accuracy                                 ±0.3ºC Mattress temperature uniformity                                  <2ºC Infant Bed tilt angle                                              ±10° LED observation light function                                      3W Warm-up time(from 25ºC)                                        <30min Heater head horizontal                                            ±90° Distance from heater to mattress                                   80cm Mattress size                                                   67cmX54cm              APGAR Timer range                               0~99h59min,singal per min at first 1h Heating power                            0-100%in5%step                                                                    Phototherapy Irradiance                                          20-70μw/c/nm Standard configuration Main body (including the Radiant source, Control system,Infant bed, Bracket), X-ray cassette , Observe light ,I.V.pole, Skin temperature sensor, Tray, Mattress, Transparent protector, Castors , Drawers Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral) Reusable AMBU bag for child - 2 pcs Reusable AMBU bag for adult - 2 pcs  Reusable laryngoscope 1 pcs Hospital Furniture,High Quality Hospital Furniture,Hospital Furniture Details, STANDARD STEEL WuYi AnBo Medical Equipment Manufacturing Co.,Ltd , http://www.anbomedical.com
MR-700 Infant Radiant Warmer
Model NO.: MR-700
Origin: China
Model NO.: MR-700
Origin: China