MR-700 Infant Radiant Warmer

Model NO.: MR-700
Origin: China
Model NO.: MR-700
Origin: China

MR-700 with LCD touch screen  Phototherapy Unit  Pulse Oximetry

Function features

 

Microprocessor based servo controlled temperature system

 

The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic

 

APGAR timer to record therapy time

 

Audible and visual  Alarm functions :

 

Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature

 

LED observation light adjustable,brightness adjustable

 

Heater head can be adjusted  ±90°horizontally

 

Convenient X-ray cassette board under infant bed

 

Tilt angle of infant bed is adjustable

 

Four Transparent protector folded with 2 infusion seals

 

With RS-232 connector,2 trays and 2 drawers

 

Skin temp T1,T2; Temp value and trend on 8″LCD Touch screen

 

Pulse oximetry, APGAR timer and other parameters display on 8″LCD  screen

 

BL -60D Phototherapy unit,Sillicone Ambu-bag set, Laryngoscope set

Technical data

Power supply                              AC110/220V   60/50Hz

Power input                               1000VA

                  Environment temperature                    18ºC~30ºC

Operating          Environment relative humidity                 30%~75%

conditions          Atmospheric Pressure                        700~1060hpa

                  Environment air velocity of flow                 <0.3m/s

Skin Temperature control range                                   32ºC~38ºC

Skin temperature control accuracy                                 ≤0.5ºC

Skin temperature sensor accuracy                                 ±0.3ºC

Mattress temperature uniformity                                  <2ºC

Infant Bed tilt angle                                              ±10°

LED observation light function                                      3W

Warm-up time(from 25ºC)                                        <30min

Heater head horizontal                                            ±90°

Distance from heater to mattress                                   80cm

Mattress size                                                   67cmX54cm              

APGAR Timer range                               0~99h59min,singal per min at first 1h

Heating power                            0-100%in5%step                                                                    Phototherapy Irradiance                                          20-70μw/c/nm

Standard configuration

Main body (including the Radiant source, Control

system,Infant bed, Bracket), X-ray cassette ,

Observe light ,I.V.pole, Skin temperature sensor,

Tray, Mattress, Transparent protector, Castors ,

Drawers

Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral)

Reusable AMBU bag for child - 2 pcs

Reusable AMBU bag for adult - 2 pcs

 

Reusable laryngoscope 1 pcs

MR-700 with LCD touch screen  Phototherapy Unit  Pulse Oximetry

Function features

 

Microprocessor based servo controlled temperature system

 

The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic

 

APGAR timer to record therapy time

 

Audible and visual  Alarm functions :

 

Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature

 

LED observation light adjustable,brightness adjustable

 

Heater head can be adjusted  ±90°horizontally

 

Convenient X-ray cassette board under infant bed

 

Tilt angle of infant bed is adjustable

 

Four Transparent protector folded with 2 infusion seals

 

With RS-232 connector,2 trays and 2 drawers

 

Skin temp T1,T2; Temp value and trend on 8″LCD Touch screen

 

Pulse oximetry, APGAR timer and other parameters display on 8″LCD  screen

 

BL -60D Phototherapy unit,Sillicone Ambu-bag set, Laryngoscope set

Technical data

Power supply                              AC110/220V   60/50Hz

Power input                               1000VA

                  Environment temperature                    18ºC~30ºC

Operating          Environment relative humidity                 30%~75%

conditions          Atmospheric Pressure                        700~1060hpa

                  Environment air velocity of flow                 <0.3m/s

Skin Temperature control range                                   32ºC~38ºC

Skin temperature control accuracy                                 ≤0.5ºC

Skin temperature sensor accuracy                                 ±0.3ºC

Mattress temperature uniformity                                  <2ºC

Infant Bed tilt angle                                              ±10°

LED observation light function                                      3W

Warm-up time(from 25ºC)                                        <30min

Heater head horizontal                                            ±90°

Distance from heater to mattress                                   80cm

Mattress size                                                   67cmX54cm              

APGAR Timer range                               0~99h59min,singal per min at first 1h

Heating power                            0-100%in5%step                                                                    Phototherapy Irradiance                                          20-70μw/c/nm

Standard configuration

Main body (including the Radiant source, Control

system,Infant bed, Bracket), X-ray cassette ,

Observe light ,I.V.pole, Skin temperature sensor,

Tray, Mattress, Transparent protector, Castors ,

Drawers

Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral)

Reusable AMBU bag for child - 2 pcs

Reusable AMBU bag for adult - 2 pcs

 

Reusable laryngoscope 1 pcs

Hospital Furniture

Hospital Furniture,High Quality Hospital Furniture,Hospital Furniture Details, STANDARD STEEL

WuYi AnBo Medical Equipment Manufacturing Co.,Ltd , http://www.anbomedical.com