Common troubleshooting of the dryer

Close the power supply, the computer board is not lit?

Answer: 1. Check if the insurance is burned out (the GW401D computer board comes with a fuse on the back, now 35 baking, 50 baking)

2. Electric heating dryer Check whether the temperature controller is turned on 3.12, 16, 20, 100. Check whether the transformer is in good condition and the drum is not turned.

Answer: 1. Check if the contactor is closed. 2. Check if the insurance is burnt. 3. Check if the thermal protection is in normal working condition. 4. Check if the belt is too loose. 5. Check if the motor is burnt. 6. Check if the power supply is out of phase. rise?

Answer: (1) Check if the inlet valve is open (2) Check if the solenoid valve is intact (3) Check if the computer board has output (4) Check if the trap is intact (5) Check if the fan is turning (6) Is the internal fluff of the machine? Unclear (7) Whether the external exhaust chimney of the dryer is not smooth (8) Is the heater on the heater unprotected for a long time?

Answer: 1. Check if the contactor is closed. 2. Check if the insurance is burnt. 3. Check if the thermal protection is in normal working condition. 4. Check if the motor is burnt. 5. Check if the power supply is missing.

UBM Series

Specifications:
High Resolution Image
Liner Scanning Method
100% Bandwidth with Short-Pulse Technology
Safe in Operations
No Abrasion of Cornea
No Cross Infection
Convenient
More Probe Shells Offered
Easy to Exchange Probe Shell
Adjustable Focus by Probe Shell
Transducer: 35MHz/50MHz
Scan: Linear scan
Scanning Range: 16mm*10mm 35MHz
10mm*6.5mm 50MHz
Image pixel: 1024*655
Resolution: axial≤0.05mm, lateral≤ 0.1mm

Gain: 30-105 dB


SAB-200 A/B Scan with normal, vitreous body enhancement, retina observation mode, mainly used for diagnosis of intraocular diseases, display the location, shape range of the focus of infection and the relationship with the surrounding tissue. Can be diagnosed vitreous opacity, retinal detachment, eye base tumors etc. eye diseases. A scan is used to measure anterior chamber depth, lens thickness, axial length, calculate diopter of implant IOL as well.

B scan:
Frequency: 10MHz/20MHz (optional) ,Magnetic driven, noiseless
Scanning Mode: Sector Scanning
Magnify:Multi continuous magnification,Real-Time magnification
Resolution: Lateral ≤0.3mm;Vertical≤0.2mm
Geometry position precision: Lateral ≤10%;Vertical≤5%
Depth:60mm
Enhance the part of vitreous body and retina
Gain of probe:30dB-105dB
Scanning Angle:53°
Gray Scale: 256
False Color: Multi colors. OCT
measurement type: multigroup distances, perimeters and areas
Image postprocessing: multiple curves processing, Pseudo-color processing curve
Movies: 100 images movie review, AVI JPG format image output

A scan:
Frequency:10MHz, with LED
Depth: 40mm
Precision:±0.05 mm
Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
Eye mode: Phakic / Aphakic / Dense / Various IOL
IOL Formula: SRK-II, SRK-T, HOFFER-Q, HOLLADAY,BINKHORST-II, HAIGIS
Stat. Calculation: Average and standard deviation
Store: 10 Scanning results for each eye
Others:
Display Mode :B.B+B.B+A.A
Hint: preset keyword
Case Search:Multi-keywords
Working Platform: Windows XP.VISTA.WINDOWS7
User-defined report template poor credit secured loans


Ubm Ultrasound Machine For Eyes,Ultrasound Biomicroscopy Microscope,Ultrasound Biomicroscopy And Pachymetry,Ultrasound Biomicroscopy System

Guangzhou Sonostar Technologies Co., Limited , https://www.sonoeye.com